Note

Do not mount the BlueDiamond reader on or near a metal surface. The metal can weaken the reader range.  Please note that the readers are equipped with an optical tamper sensor and if that sensor is open, it will not read Access Contrrol cards.  Place the reader securley against mount to prevent from not reading.

Use the following illustrations as a general guidance for mounting, fixing, and connecting the readers. Refer to the manufacturer documentation when configuring your access security system. Follow the correct wire installation using the reader wiring diagrams and LED functionality charts in this guide.

  1. Pull the bottom edge of the reader module away from the backplate and lift up.


  2. Mount the reader backplate to a flat surface using suitable hardware. The diameter should be no greater than 0.15 in (4mm).


  3. Refer to the appropriate reader interface wiring diagram and use the reader terminal connection call-outs in the following chart to connect the reader. Refer to Wiring Readers.


  4. Position the reader module along the top-edge and affix the lugs correctly with the recesses at the top of the backplate.
  5. Swing the bottom edge of the module down and forward until the unit clicks shut.


  6. Secure the reader to the backplate using the supplied M3x10mm screw or use a security screw.