An unsecured reader mode is supported by Aperio locks when either the First Card Unlock or Double Card Presentation features are enabled. For First Card Unlock, there must be a predetermined time and duration for this mode. This is done by setting up a schedule for the reader mode change and configuring the First Card Unlock option. During the configured time interval, the first card with a valid access grant - entry occurred causes the Aperio lock to enter an unlocked state. The Aperio lock is then automatically relocked at the end of the configured time interval (the door returns to the off-schedule reader mode).
To configure this reader mode, configure the schedule, make sure First Card Unlock is enabled for the lock, and then assign the scheduled reader mode.
First card unlock authorized must be enabled for people via People groups with access to readers configured for first card unlock. This option gives members of such People groups the authority required for unlocking a door when the reader is in a card unlock mode.
Related Topics